Navigation

State Overview of Implemented Energy Efficiency Measures in 18 Public Buildings in FBiH

 

0-02-05-4111919d5151d91588fb26ada46c73109d7759565a153e72944bdb8b005631ef...

 

Implementation of the energy efficiency measures in 18 sub-projects, in 2016., within the World bank’s project “Bosnia Energy Efficiency Project”, among the other, was aimed at improvement of thermotechnical characteristics of those objects. Through production of the energy certificates within the project, specific results of successful implementation are visible, which are referred to the specific needs for energy by useful area unit and leveling up to higher grade of energetics.

 

0-02-04-a863d869219e649411f6172fcb819f611159f07b200163101d8a58c16132d56d...

 

 

Spreadsheet with the 18 public purpose use objects shows that the conditions for maximal allowed consumption of heat energy were met after the implementation of the energy efficiency measures, for those kind of objects according to the Rulebook of technical requirements for object heating protection and rational use of energy.  Calculation was conducted with BAS EN ISO 13760: 2005 standard.

 

0-02-05-18acdc94db83cb141512173b57b5fab06534442dd1b29736092878319107fd2e...

 

0-02-05-4ff40568db206f7294772ad03a3a9cecd32543a103043f1f4dbba16d7638478a...

 

Total energy consumption for these 18 objects at the annual level before warming up amounted 14.581.252 [kWh/a], while after the implementation of energy efficiency measures energy consumption amounted 6.379.789 [kWh/a] which implicates to 8.201.463 [kWh/a] savings.

 

No. Object name Adress and City Energy class before  EE measures implementation Energy class after EE measures implementation Energy consumption before EE measures implementation kWh/m2 a Energy consumption after  EE measures implementation kWh/m2 a
1 JU OŠ Crnići Aladinići,  Stolac C B 116 49
2 JU SŠ Juraj Dalmatinac Kralja Zvonimira 24, Mostar C B 126 60
3 ZU Dom Zdravlja Sulje Čilića 15, Jablanica D B 156 55
4 JU SŠ Konjic Maršala Tita 80, Konjic D B 163 55
5 JU OŠ Zahid Barudžija Omladinska 14, Vogošća E B 195 51
6 JU Prva osnovna škola Safvet-bega Bašagića bb, Zavidovići E B 188 49
7 JU IV Osnovna škola Salke Šestića 23 , Mostar B A 94 40
8 ZU Opća bolnica Braće Pobrić 17, Tešanj C B 120 62
9 JU OŠ Fra Didaka Buntića Kralja Tomislava 94, Čitluk B A 86 34
10 OŠ Hamdija Kreševljaković Šehida 2, Kakanj D B 161 47
11 OŠ Hašim Spahić Krajiška bb , Ilijaš F B 260 71
12 OŠ Musa Ćazim Ćatić Školska bb, Zenica D B 138 61
13 JU OŠ Srednje Srednje bb, Ilijaš D B 150 88
14 JU Srednja mješovita škola Zagrebačka bb, Žepče C B 110 50
15 JU Srednja škola R.Boškovića 9, Čapljina E A 187 40
16 KC Mostar Psihijatrija KMV Humskog bb, Mostar D A 137 45
17 JZU UKC Tuzla Rate Dugonjića bb, Tuzla E B 185 49
18 UKC Ortopedija Sarajevo Bolnička 25, Sarajevo E B 195 56

 

 

Spreadsheet 1.  Overview of the public use objects with energy class information before and after implementation of energy efficiency measures

Screen Shot 2017-04-21 at 19.05.48

 

Energy savings by percentage, regarding to the condition of objects before warming up, amounts 56%, whereby implementation success and investment validity is confirmed in the best way.